MEELSA Work Shop Experience

Generator Testing, and Re-wedging

Generator Stator Inspection

Retaining Rings disassembly, Field inspection and Testing

Repaired connection rings

Major Outage and Generator Modification

Inspection and Test of Generator, due to Oil Flooding.

Inspection and Test the collector assembly and brush rigging which brushes and brush holders damaged. The outer collector ring was recommended for grinding on site.

Performing RSO test on generator field.

Inspected and investigates ground bars

Electrical test also performed El-Cid Test

Performed (ETC) Electronic Technical Correspondence

Installed Block-Flux Prober

Generator rotor testing.
Jebel Ali GE Repair Center Shop
1.GE Generator Field ,BBC Generator Field, Alstom Generator Field
1.Cleaned/polishing coil copper.
2.Removing of bore copper, studs assembly and testing.
3.Rewinding and bake rigging preparation.
4.Assembly of wedges.
5.Insulate end winding with steel plate.
6.Assembly of amortissuer and retaining ring
Site Work Experience

BATAAN POWER PLANT ABB Generator Field 105,000MVA
1.Repair brace 1. support exciter.